serial number | parameter name | factory set | set range | introduction |
C01 | input velocity coefficient | 100% | 10-500% | trimming input ,the rev speed of tranction axie |
C02 |
output velocity coefficient | 100% | 10-500% |
C03 | zero set | 0 | 0.1(zero set) | parameter of tension zero set and calbrating |
C04 | calibration parameters | 20.0kg | 0.0-200.0kg |
C05 | tension calibrating | 0 | 0.1(calibrating) |
C06 | PID set direction | 1 | 1(forward)、—1 (reverse) | controller parameter of PID |
C07 | PID output percentage | 10.0% | 0.0%-100.0% |
C08 | PID set speed | 10.0% | 0.0%-100.0% |
C09 | display smoothing | 2.0s | 0.0-4.0s | display and output smoothing parameters |
C10 | output smoothing | 10ms | 0-1000ms |
C11 | tension measure range | 30.0kg | 0.0-200.0kg | measuring range of tension and critical alarm of maximum and minmum |
C12 | alarm of maximum tension | 60.0kg | 0.0-210.0kg |
C13 | alarm of minimum tension | 0.0kg | 0.0-100.0kg |
C14 | diameter of main axie | 60mm | 1-1000mm | linear speed input signal is the parameter of proximity switch
|
C15 | teeth number of main axie | 1.0gear | 0.1-100.0gear |
C16 | adress of communication | 2 | 0-127 | communication parameters of RS485 |
C17 | communication Baud rate | 9600 | 4800、9600、19.2k |
C18 | mode of tension sensor | 0 | 0(differerntial)、 1(strain) | parameters is up to the mode of tension sensor |